EIS SETTINGS LIMITS: cont = 2 (contrast) light = 128 (backlight intensity) interval = 30 (countdown timer) max OP = 99 min OP = 50 max OT = 220 max RPM = 4900 min fuel = max AUX2 (SCP) = 12 max AUX3 (GBT) = 210 max AUX4 (FPr) = 38 min AUX4 (FPr) = 18 max AUX5 (amps) = 58 min AUX5 (amps) = 5 max H2O = 220 max volt = 15.6 min volt = 12.8 display = 1 (favorite display page) set interval to 30 CONFIGURATION: DISPLAY #1: Tach MAP H2O OT/OP FPr Volts DISPLAY #2: Tach amps OAT GBT OT/OP Flow Volts AUX SETTINGS: AUX1 = MAP 1SF = 446 1OFF = 66 + D AUX2 = SCP 2SF = 51 2OFF = 3 + I AUX3 = GBT 3SF = 135 3OFF = 11 - I AUX4 = FPr 4SF = 91 4OFF = 15 + I AUX5 = Amp 5SF = 186 5OFF = 357 + I AUX6 = unused 6SF = 100 6OFF = 0 + I +/- = tells whether each AUX port is proportional or inverse D/I = tells whether each AUX port is an integer or has a decimal point I = 3 display characters, D=4 char OTHER SETTINGS: Tach P/R = 2 FloCal = 200 FloBias = 0 AltCor = 128 Tim_RPM = 0 (engine speed to affect hour meter) DISABLED PAGES: 3,4,6,7,8,11,15 USER PAGE CONFIGURATION: (16 char/row) 1D1 = Tach 1P1 = 1 1D2 = Ax1 (MAP) 1P2 = 7 1D3 = H2O 1P3 = 14 1D4 = Off 1P4 = 14 1D5 = OT 1P5 = 17 1D6 = / 1P6 = 20 1D7 = OP 1P7 = 21 1D8 = Ax4 (FPr) 1P8 = 24 1D9 = Volt 1P9 = 29 1D10 = Off 1P10 = 0 1D11 = Off 1P11 = 0 1D12 = Off 1P12 = 0 2D1 = Tach 2P1 = 1 2D2 = Ax5 (amps) 2P2 = 6 2D3 = OAT 2P3 = 10 2D4 = Ax3 (GBT) 2P4 = 14 2D5 = OT 2P5 = 17 2D6 = / 2P6 = 20 2D7 = OP 2P7 = 21 2D8 = Flow 2P8 = 24 2D9 = Volt 2P9 = 29 2D10 = Off 2P10 = 0 2D11 = Off 2P11 = 0 2D12 = Off 2P12 = 0 GD/GP1-9 is for graphical leaning display, and not applicable to us Peak=10 is for graphical leaning, and not applicable to us don't forget to allow for FUEL LEVEL